ZC454 (chiller 26-824 kW)
ZC454 - chiller with R454 refrigerant gas
ZC454B series is a range of air-cooled chillers, of low GWP, with cooling capacities from 18 kW to 884 kW.
The entire range is the result of an appropriate design that has led to the adoption of measures and the use of components to make it safe to operate with A2L refrigerants, classified as mildly flammable.
The unit color is:
White RAL7035
Blue RAL 5002
COOLING CIRCUIT
The refrigeration circuit is made in a simple way to reduce any type of vibration on the brazing points. This range is equipped with brazed plate evaporator and is designed and engineered to have high energy efficiency.
In fact, the copper pipes of which it is composed have very few welding points to eliminate refrigerant gas leaks. The thickness of the copper is high, and this allows an excellent fusion of the material and consequent brazing to perfection.
The cooling circuit consists of SCROLL compressors, complete with Carter resistance. The units, depending on the power, can be composed of one or four independent refrigeration circuits, with one or two compressors each.
ELECTRICAL BOARD
The electrical board has quite large sizes and it’s located in a specific area surrounded by its frame.
Each electric is equipped with a lock door device.
The standard power supply is 400 ±10%/3/50Hz. Optional: power supply 460 ±10%/3/60Hz
HYDRAULIC MODEL
Our range can include the hydraulic model or not, therefore it’s an option that can be required according to the type of system.
It can be shaped in different ways:
1. no water tank and no pump
- just tank
3. just pump or double pump
4. water tank and pump or double pump 5. water tank, primary and secondary pump
The water tank is standardly equipped with water filter to protect the evaporator.
TEST
Each chiller is tested in the testing room.
During this phase, the following operation modes are checked:
-correct assembly of the components
-components fastening
-operation in accordance with safety standards
-electrical test in accordance with Standard EN60204
-operation of the electrical board
-chiller performance under standard conditions
VERSIONS
ZH_454B= Heat Pump (hot and cold water)
ZC454B_PR= Primary and Secondary Pump
ZC454B_Re= Rental
MORE INFORMATION:
write to info@chiller-frigoriferi.it
by phone, dial the number + 39 049 8792774
by fax, dial number: +39 049 8797940
by email, push ASK FOR MORE INFORMATION OR OFFER
ZC454 - chiller models
Wide range of chiller models with R32 refrigerant gas with a cooling capacity from 26 up to 824 kW
ZC454_STD 28.11
ZC454_STD 31.11
ZC454_STD 36.11
ZC454_STD 42.11
ZC454_STD 48.12
ZC454_STD 56.12
ZC454_STD 61.12
ZC454_STD 71.12
ZC454_STD 83.12
ZC454_STD 95.12
ZC454_STD 110.12
ZC454_STD 120.12
ZC454_STD 140.12
ZC454_STD 160.12
ZC454_STD 180.12
ZC454_STD 220.24
ZC454_STD 240.24
ZC454_STD 270.24
ZC454_STD 310.24
ZC454_STD 350.24
ZC454_STD 400.24
ZC454_STD 450.24
ZC454_STD 480.48
ZC454_STD 540.48
ZC454_STD 610.48
ZC454_STD 660.48
ZC454_STD 750.48
ZC454_STD 790.48
ZC454_STD 890.48
MORE INFORMATION:
write to info@chiller-frigoriferi.it
by phone, dial the number + 39 049 8792774
by fax, dial number: +39 049 8797940
by email, push ASK FOR MORE INFORMATION OR OFFER